- Subrack for K-System
- Replacement for subrack of the E-System
- Max. 33 slots for isolators
- Short design (211 mm mounting depth)
- Connection via marshalling patchboards
- Partial and combined assembly possible
- Complete wiring according to customer requirements
- Allows to retain cable routing in the switch cabinet
- No structural changes on the switch cabinet required
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1Â input and 2Â outputs)
- Dual output 0/4 mA … 20 mA or 0/1 V … 5 V
- Terminal blocks with test sockets
- Up to SIL 3 acc. to IEC/EN 61508
Electric power supply; removable terminals; supply voltage 92 V … 265 V AC; output voltage 24 V DC, 4 A; suitable for Power Rail supply
- 115/230 V AC supply
- Output 24 V DC, 4 A
- Fused output
- Power Rail connection
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- HART field device input with transmitter power supply
- Usable as signal splitter (1 input and several outputs)
- 2 relay contact outputs (change-over contacts)
- 3 analog outputs 4 mA … 20 mA
- Sink and source mode output
- Configurable by keypad
- 1-channel isolated barrier
- 24 V DC supply (power rail)
- Current output up to 650 Ω load
- HART-IP and valve positioner
- Line fault detection (LFD)
- Accuracy 0.1 %
- Up to SIL 2 (SC 3) acc. to IEC/EN 61508
- 1-channel isolated barrier
- 24 V DC supply (Power Rail)
- Input for approved dry contacts or SN/S1N sensors
- Relay contact output
- Fault indication output
- Line fault detection (LFD)
- Up to SIL 3 acc. to IEC/EN 61508
- Up to PL d acc. to EN/ISO 13849
- 1-channel isolated barrier
- 24 V DC supply (power rail)
- Dry contact or NAMUR inputs
- 2 active transistor outputs
- Usable as signal splitter (1 input and 2 outputs)
- Reversible mode of operation
- Line fault detection (LFD)
- Up to SIL 2 (SC 3) acc. to IEC/EN 61508
- 2-channel isolated barrier
- 24 V DC supply (Power Rail)
- Dry contact or NAMUR inputs
- Active transistor output
- Line fault detection (LFD)
- Reversible mode of operation
- Up to SIL 2 (SC 3) acc. to IEC/EN 61508
- 1-channel isolated barrier
- 24 V DC supply (power rail)
- Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
- Output 4 mA … 20 mA current sink/current source
- Terminals with test points
- Up to SIL 2 acc. to IEC/EN 61508
- 1-channel isolated barrier
- 115/230 V AC supply
- Input for approved dry contacts or SN/S1N sensors
- Relay contact output
- Fault indication output
- Line fault detection (LFD)
- Up to SIL 3 acc. to IEC/EN 61508
- Up to PL d acc. to EN/ISO 13849
R2000 Detection, 2D LiDAR sensor for precise field monitoring, measuring range to object up to 10Â m
- 4 freely programmable monitoring fields
- 4 inputs/outputs (selectable)
- High angle resolution
- 360°-angle of measurement
- Measuring method PRT (Pulse Ranging Technology)
R2000 Detection, 2D LiDAR sensor for precise field monitoring, measuring range to object up to 30Â m
- 4 freely programmable monitoring fields
- 4 inputs/outputs (selectable)
- High operating range
- 360°-angle of measurement
- Measuring method PRT (Pulse Ranging Technology)
- Very narrow scan plane