Intrinsic Safety Barriers

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input for 2-wire SMART transmitters and current sources
  • Signal splitter (1 input and 2 outputs)
  • Dual output 0/4 mA … 20 mA or 0/1 V … 5 V
  • Terminal blocks with test sockets
  • Up to SIL 3 acc. to IEC/EN 61508

Attachments:
KCD2-STC-Ex1.2O.ES Data Sheet
KCD2-STC-Ex1.2O.ES EU Declaration of Conformity

Electric power supply; removable terminals; supply voltage 92 V … 265 V AC; output voltage 24 V DC, 4 A; suitable for Power Rail supply

  • 115/230 V AC supply
  • Output 24 V DC, 4 A
  • Fused output
  • Power Rail connection

Attachments:
KFA6-STR-1.24.4 Data Sheet
KFA6-STR-1.24.4 EU Declaration of Conformity

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • HART field device input with transmitter power supply
  • Usable as signal splitter (1 input and several outputs)
  • 2 relay contact outputs (change-over contacts)
  • 3 analog outputs 4 mA … 20 mA
  • Sink and source mode output
  • Configurable by keypad

Attachments:
KFD2-HLC-Ex1.D.2W Data Sheet
KFD2-HLC-Ex1.D.2W EU Declaration of Conformity

  • 1-channel isolated barrier
  • 24 V DC supply (power rail)
  • Current output up to 650 Ω load
  • HART-IP and valve positioner
  • Line fault detection (LFD)
  • Accuracy 0.1 %
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508

Attachments:
KFD2-SCD2-Ex1.LK Data Sheet
KFD2-SCD2-Ex1.LK EU Declaration of Conformity

  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input for approved dry contacts or SN/S1N sensors
  • Relay contact output
  • Fault indication output
  • Line fault detection (LFD)
  • Up to SIL 3 acc. to IEC/EN 61508
  • Up to PL d acc. to EN/ISO 13849

Attachments:
KFD2-SH-Ex1 Data Sheet
KFD2-SH-Ex1 EU Declaration of Conformity

  • 1-channel isolated barrier
  • 24 V DC supply (power rail)
  • Dry contact or NAMUR inputs
  • 2 active transistor outputs
  • Usable as signal splitter (1 input and 2 outputs)
  • Reversible mode of operation
  • Line fault detection (LFD)
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508

Attachments:
KFD2-ST3-Ex1.LB Data Sheet
KFD2-ST3-Ex1.LB EU Declaration of Conformity

  • 2-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Dry contact or NAMUR inputs
  • Active transistor output
  • Line fault detection (LFD)
  • Reversible mode of operation
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508

Attachments:
KFD2-ST3-Ex2 Data Sheet
KFD2-ST3-Ex2 EU Declaration of Conformity

  • 1-channel isolated barrier
  • 24 V DC supply (power rail)
  • Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
  • Output 4 mA … 20 mA current sink/current source
  • Terminals with test points
  • Up to SIL 2 acc. to IEC/EN 61508

Attachments:
KFD2-STC5-Ex1 Data Sheet
KFD2-STC5-Ex1 EU Declaration of Conformity

  • 1-channel isolated barrier
  • 115/230 V AC supply
  • Input for approved dry contacts or SN/S1N sensors
  • Relay contact output
  • Fault indication output
  • Line fault detection (LFD)
  • Up to SIL 3 acc. to IEC/EN 61508
  • Up to PL d acc. to EN/ISO 13849

Attachments:
KHA6-SH-Ex1 Data Sheet
KHA6-SH-Ex1 EU Declaration of Conformity

  • 1-channel
  • Control circuit EEx ia IIC
  • 230 V AC supply voltage
  • Reversible mode of operation
  • Lead breakage (LB) monitoring
  • 1 relay contact output (change-over contact)

Attachments:
WE77/Ex-1 230V Data Sheet
WE77/Ex-1 230V EU Declaration of Conformity